Enron Mail |
This is what Scot Chambers has sent me so far.
Ben ---------------------- Forwarded by Benjamin Rogers/HOU/ECT on 02/07/2000 10:09 AM --------------------------- Scot Chambers@ENRON_DEVELOPMENT 02/04/2000 01:34 PM To: Benjamin Rogers/HOU/ECT@ECT cc: Subject: Re: Ben, I have a reference document called Gas Turbine World Handbook in which I look up these type of answers as well for ballpark info. They are the "preliminary answer" to your question and should be treated as so. Please keep in mind that these are numbers from a magazine, not from our internal Performance/Cycles group under Gary Bush (within EECC). They are the dept that the Dev Engineer typically consults with to arrive at a project's capacity and efficiency, both from a new & clean standpoint and an average degradation standpoint. The depts within EECC/NEPCO also come up with the total installed costs. It is their numbers that are the ones that we typically bid in a proforma, as such, they are a part of the deal approval process (DASH). Their buy in is important because in addition to the numbers that OEM's provide us, they factor in experience, judgement, unique project characteristics, design basis, intake/exhaust losses, etc. They also look at the net power for the Plant, not just the equipment itself. Having caveat'ed these numbers, I would respond to your questions below as follows: 1. PG7241FA Capacity: 171,700 kW each @ generator terminals (ISO conditions, gas fired @ baseload) -- does not include auxiliaries usage, duct losses 2. 1,060 MW Net Plant @ ISO, gas fired 3. 6,040 Btu/kWh LHV @ ISO, gas fired 4. Plug figure for GTG may be $32,500,000 each. No idea on the ST, swag at $175/kW. Power island turnkey for 2x1 may be $375/kW (does not include alot of stuff such as add'l options, development costs, tie-ins, permitting, spares, etc, etc, etc) Hope this is useful to you somehow, but please go to the source (described above) for anything that we are going to hang our hat on. Benjamin Rogers@ECT 02/04/2000 09:39 AM To: Scot Chambers/ENRON_DEVELOPMENT@ENRON_DEVELOPMENT cc: Subject: With regards to our conversation yesterday, I am loking for basic economics regarding GE 7FA's. Such as, 1. output per turbine; 2. output for 4 7FA and 2 steam turbines; 3. Heat Rates; and 4. cost per turbine and steam turbine. Total plant output will need to be 1000 MW's and will be run as a combined cycle facility. If you could get me these numbers by the end of the day or call me to discuss what you currently have that would be great. This project is not due till Wednesday. Thanks Ben
|